? ?客(ke)戶至(zhi)上,朗普極速響應
? ? ? ? ?——朗普技術團隊緊急(ji)支援南部戰(zhan)區一五七分院檢驗科
4月(yue)10日(ri),朗普技術(shu)保障小組(zu)接到客戶反映(ying),南(nan)部戰(zhan)區一五(wu)七分(fen)院(yuan)(yuan)(yuan)檢(jian)驗科室(shi)紫(zi)(zi)外(wai)線(xian)(xian)殺(sha)菌設備使用故障,紫(zi)(zi)外(wai)燈管輻射(she)劑(ji)量(liang)強(qiang)度(du)銳減(jian)。朗普接到醫院(yuan)(yuan)(yuan)反饋后(hou)高度(du)重視(shi),迅速組(zu)織(zhi)技術(shu)團隊進行產品跟(gen)蹤調(diao)查,經初步與院(yuan)(yuan)(yuan)方溝通(tong)初步懷疑是(shi)由于該科室(shi)紫(zi)(zi)外(wai)線(xian)(xian)燈配套(tao)鎮流器故障或(huo)是(shi)由于所(suo)使用的(de)紫(zi)(zi)外(wai)線(xian)(xian)燈管達到使用壽命,燈管老化損耗和燈體黑頭導致紫(zi)(zi)外(wai)線(xian)(xian)輻射(she)強(qiang)度(du)下降。
11日中(zhong)午(wu),朗普(pu)技(ji)術(shu)團隊(dui)來到(dao)南部戰(zhan)區總院一五七分院檢(jian)驗科(ke),進行(xing)(xing)紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)燈(deng)照(zhao)(zhao)射(she)(she)檢(jian)查,初步檢(jian)驗發現(xian)清潔室與(yu)洗消室兩(liang)(liang)組(zu)(zu)(zu)(zu)紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)殺菌(jun)燈(deng)開啟(qi)后照(zhao)(zhao)射(she)(she)可見(jian)光亮度衰減,紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)燈(deng)開啟(qi)時異常閃(shan)爍。朗普(pu)技(ji)術(shu)人(ren)(ren)(ren)員(yuan)使用(yong)(yong)LS125型紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)輻(fu)(fu)照(zhao)(zhao)計對(dui)分別對(dui)洗消室、紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)燈(deng)組(zu)(zu)(zu)(zu)以及配套鎮(zhen)流器進行(xing)(xing)現(xian)場測定(ding)(ding)(ding),輻(fu)(fu)照(zhao)(zhao)測試顯示:在(zai)額定(ding)(ding)(ding)高度1m、照(zhao)(zhao)射(she)(she)5min的額定(ding)(ding)(ding)洗消間兩(liang)(liang)組(zu)(zu)(zu)(zu)紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)燈(deng)管(guan)紫(zi)(zi)外(wai)(wai)(wai)(wai)輻(fu)(fu)照(zhao)(zhao)強(qiang)度分別為275μw/cm2、25μw/cm2(國(guo)家(jia)標準GB19258規定(ding)(ding)(ding)UVC40W紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)殺菌(jun)標準為135μw/cm2);清潔室兩(liang)(liang)組(zu)(zu)(zu)(zu)紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)燈(deng)組(zu)(zu)(zu)(zu)輻(fu)(fu)照(zhao)(zhao)劑量強(qiang)度分別為250μw/cm2、25μw/cm2,技(ji)術(shu)人(ren)(ren)(ren)員(yuan)根據測試參數判定(ding)(ding)(ding),洗消間與(yu)清潔室四組(zu)(zu)(zu)(zu)紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)殺菌(jun)燈(deng)組(zu)(zu)(zu)(zu)中(zhong),兩(liang)(liang)組(zu)(zu)(zu)(zu)紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)燈(deng)管(guan)達到(dao)產品使用(yong)(yong)壽命,建(jian)議進行(xing)(xing)無害報廢處理并(bing)進行(xing)(xing)更(geng)換(huan)全新的紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)燈(deng)組(zu)(zu)(zu)(zu)。在(zai)征得院方同意后,朗普(pu)技(ji)術(shu)人(ren)(ren)(ren)員(yuan)對(dui)故障燈(deng)組(zu)(zu)(zu)(zu)進行(xing)(xing)全新更(geng)換(huan),現(xian)場進行(xing)(xing)產品輻(fu)(fu)照(zhao)(zhao)測試。經測試:更(geng)換(huan)后兩(liang)(liang)組(zu)(zu)(zu)(zu)新紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)燈(deng)組(zu)(zu)(zu)(zu)現(xian)場輻(fu)(fu)射(she)(she)強(qiang)度達到(dao)280μw/cm2以上,有效超過(guo)紫(zi)(zi)外(wai)(wai)(wai)(wai)線(xian)(xian)殺菌(jun)輻(fu)(fu)射(she)(she)國(guo)家(jia)標準。
在(zai)新冠肺(fei)炎(yan)的(de)(de)攻堅(jian)克難階段,一(yi)(yi)五(wu)七分院承(cheng)當著南部戰區(qu)和(he)廣州東部疫情(qing)(qing)防(fang)(fang)控(kong)任務(wu)(wu),為(wei)全(quan)省有力(li)(li)有序抗擊疫情(qing)(qing)作出(chu)了重大貢獻(xian),充(chong)分彰顯了救死扶(fu)傷、大愛無疆、無私(si)奉獻(xian)的(de)(de)責任擔當。在(zai)疫情(qing)(qing)防(fang)(fang)控(kong)的(de)(de)攻堅(jian)克難階段,一(yi)(yi)五(wu)七分院充(chong)分利用紫外線殺(sha)菌燈優勢,超前準備醫(yi)療(liao)設備和(he)醫(yi)護力(li)(li)量、強化(hua)醫(yi)療(liao)防(fang)(fang)護物資保障。朗(lang)普技(ji)術(shu)團隊積極配(pei)合一(yi)(yi)五(wu)七分院消殺(sha)防(fang)(fang)控(kong)任務(wu)(wu),迅(xun)速調配(pei)人力(li)(li)和(he)資源,排除(chu)醫(yi)療(liao)設備故(gu)障,積極支(zhi)持(chi)一(yi)(yi)五(wu)七分院疫情(qing)(qing)防(fang)(fang)控(kong)工作。
注(zhu):以上數據由朗普測試提供(gong),僅供(gong)參(can)考(kao)。